If you can't find the 240 volt motor, you could use the 120 volt motor, part # 2205033, along with a ballast resistor to limit the current flow. Whirlpool does this in many dryers where a 120 volt timer motor is in the 240 volt heater circuit. The resistor WP uses is part # 279872