    Help With Math, Calculating Total Amps

    My Frigemore has a nameplate rating of 12A. I have run it through full cycles with a recording ammeter, and the max run amps would be about 6A with brief 9A surges. Manufacturers are free to put whatever value they want on a nameplate. According to the National Electrical Code, 12A is the...
  2. Y

    50's dishwashers and GFI outlets

    GFCI Many older appliances are not GFCI-compatible. A GFCI is set to trip when the current leakage to ground is in the range of 4-6 mA. Many older appliances exceed this amount. It is not necessary by today's code to have GFCI protection on a built-in DW, but countertop outlets are required to...
  3. Y

    Turquoise Kelvinator kitchen

    on eBay http://cgi.ebay.com/Retro-Vintage-Stove-Range-Refridgerator-Dishwasher_W0QQitemZ7539479331QQcategoryZ20715QQrdZ1QQcmdZViewItem
  4. Y

    Slant-front Westy Dryer

    On EBay. http://cgi.ebay.com/Working-50s-style-westinghouse-dry-with-original-book_W0QQitemZ6201761780QQcategoryZ1400QQssPageNameZWDVWQQrdZ1QQcmdZViewItem
  5. Y

    Built-Ins!

    Cadman, I did not mean any offense. I didn't say that all engineers, et al are ignorant of proper practice. My apologies if I came across that way. In my experience, however, among DIYers who are brave enough to attempt their own wiring, those with no previous electrical knowledge are more...
  6. Y

    Built-Ins!

    Electrical Code cadman, I don't want to come off sounding overbearing and humorless, but I do hope you will think better of your cavalier know-it-all attitude regarding electrical codes and safety. As difficult as it may be to imagine, the National Electrical Code is not written by a bunch of...
  7. Y

    Isn't This Picture Fun?

    Florida & Refrigeration Refrigeration/air conditioning was invented in Florida by Dr. John Gorrie in 1851. http://fcit.usf.edu/florida/lessons/gorrie/gorrie.htm
  8. Y

    Tankless Water Heaters

    Aquastar I have had an Aquastar 125B (the most common Bosch model) since May 2002. I am very happy with it. There are only two people in my household. Tankless water heaters do not "run out" of hot water (unless you run out of fuel). They do have a limited flow rate, however. The Aquastar will...
  9. Y

    Cloth covered power cords to vinyl: date ?

    at least into the late '70s I remember when I'd go to the hardware store with my dad, I would always end up in the electrical aisle. They always had a good stock of cloth replacement cords for small appliances, although these may have been on the shelf for awhile. This would have been '78-'80...
  10. Y

    The Pope in a washer

    different to me opportunity experiences My wife says this was probably translated using BabelFish, hence the English words with German grammar. My thought was, more like YodaFish! My brother says: my theory is that dorfverkaufer is the pope's ebay account. he saw his own reflection in the...
  11. Y

    Cost of home heating oil

    BioDiesel Sounds like the alcohol content is to make the fuel stable. Actually, it is to break down the long molecules into shorter ones that won't gum up your injectors. The chemical is sodium methoxide and it is made by reacting the proper proportion of methanol and sodium hydroxide (lye)...
  12. Y

    Induction Electric Cooking

    "Well, the lower the voltage, the warmer the wires, the more heat produced, the more oil used :)" Actually, very little of US electric power is generated in oil-fired plants. But Bush does answer to the coal, gas, and nuclear interests. And yes, they do want us to go on wasting energy.
  13. Y

    Natural gas fueled heat-pump

    Robur The Robur units (which, like many RV fridges, are labelled Servel--the original Servel went out of business in the late '50s) are chillers. They chill water and then pump it through pipes to fan-coil units in the house. This is an old, proven technology, but it might be a pain to retrofit...
  14. Y

    Natural gas fueled heat-pump

    Engine-driven I'd be skeptical of a vapor-compression system with an engine-driven compressor. These have seals that begin to leak over time, not to mention periodic engine maintenance requirements. How many of us have had automotive air conditioners fail, and incurred massive repair costs...
  15. Y

    1950 Kenmore Dryer

    Looked at the nameplate, that's the way. I figured it was a 240v model anyway. No way to vent it? That's strange.